Whether you are in need of military aviation parts, NSN components, or various forms of aerospace and defense parts, Aerospace Store is a single-sourcing solution with over 2 billion product listings readily available for purchase at any time with competitive pricing. You have reached the Request for Quote (RFQ) page for part number C94490-15AY1.0, a B C Systems Inc component we feature that is listed with the NSN 6130012600134 and item name “Power Supply.” For further identification, part number C94490-15AY1.0 was also specifically produced under CAGE Code 48313 and belongs to Federal Supply Class (FSC) 6130 Converters Electrical Non Rotating. If you would like to receive specific options for procurement that have been tailored to your unique needs and restrictions alike, we ask that you please fill out and submit the form provided on this page with as much information as you can. Once our team has a chance to receive and review your offered details, a dedicated account manager will be in touch shortly after.
Note : We will not share your information to any third parties.
Items like part number C94490-15AY1.0 and others are all readily available with short lead times, and we boast rigorous quality-assurance practices to guarantee the caliber and reliability of every purchase made on our website. Beyond quality, we are fully committed to customer satisfaction, regularly exceeding industry expectations to ensure that we thoroughly and efficiently address every need. If you happen to be facing a time constraint that demands more specialized fulfillment solutions, please give us a call or email at any time to discuss the options we can provide. We are available around the clock and are always happy to assist, so do not hesitate to reach out for part number C94490-15AY1.0 and other various items of interest.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-260-0134 Item Description: Power Supply | 6130 | 012600134 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | isc | rnvc | rncc | HCC | MSDS | SADC |
C94490-15ay1.0 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 4.380 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 3.690 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.500 INCHES NOMINAL" |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 70000.0 FEET" |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING" |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT" |
APNX | INPUT VOLTAGE RATING | 105.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 125.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT" |
APPA | OUTPUT VOLTAGE RATING | -14.0 DC VOLTS MINIMUM 2ND POWER OUTPUT AND -16.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT" |
APPA | OUTPUT VOLTAGE RATING | 14.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 16.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT" |
APTQ | INPUT FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 420.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT" |
AYNH | OPERATING AMBIENT TEMP RANGE | -55.0/+100.0 DEG CELSIUS" |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT" |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT" |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT" |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT" |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 1ST POWER OUTPUT" |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 2ND POWER OUTPUT" |
CWHC | OUTPUT CONTROL LOCATION | TOP PANEL 1ST POWER OUTPUT" |
CWHC | OUTPUT CONTROL LOCATION | TOP PANEL 2ND POWER OUTPUT" |
CWHF | OUTPUT CONNECTION QUANTITY | 3 1ST POWER OUTPUT" |
CWHF | OUTPUT CONNECTION QUANTITY | 3 2ND POWER OUTPUT" |
CWHJ | OUTPUT CONNECTION TYPE | FERRULE 1ST POWER OUTPUT" |
CWHJ | OUTPUT CONNECTION TYPE | FERRULE 2ND POWER OUTPUT" |
CWHQ | INPUT CONNECTION TYPE | FERRULE SINGLE OPERATING POWER RQMT" |
CWHT | INPUT CONNECTION QUANTITY | 2 SINGLE OPERATING POWER RQMT" |
ABHP | OVERALL LENGTH | 4.380 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 3.690 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.500 INCHES NOMINAL" |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 70000.0 FEET" |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING" |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT" |
APNX | INPUT VOLTAGE RATING | 105.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 125.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT" |
APPA | OUTPUT VOLTAGE RATING | -14.0 DC VOLTS MINIMUM 2ND POWER OUTPUT AND -16.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT" |
APPA | OUTPUT VOLTAGE RATING | 14.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 16.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT" |
APTQ | INPUT FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 420.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT" |
AYNH | OPERATING AMBIENT TEMP RANGE | -55.0/+100.0 DEG CELSIUS" |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT" |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT" |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT" |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT" |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 1ST POWER OUTPUT" |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 2ND POWER OUTPUT" |
CWHC | OUTPUT CONTROL LOCATION | TOP PANEL 1ST POWER OUTPUT" |
CWHC | OUTPUT CONTROL LOCATION | TOP PANEL 2ND POWER OUTPUT" |
CWHF | OUTPUT CONNECTION QUANTITY | 3 1ST POWER OUTPUT" |
CWHF | OUTPUT CONNECTION QUANTITY | 3 2ND POWER OUTPUT" |
CWHJ | OUTPUT CONNECTION TYPE | FERRULE 1ST POWER OUTPUT" |
CWHJ | OUTPUT CONNECTION TYPE | FERRULE 2ND POWER OUTPUT" |
CWHQ | INPUT CONNECTION TYPE | FERRULE SINGLE OPERATING POWER RQMT" |
CWHT | INPUT CONNECTION QUANTITY | 2 SINGLE OPERATING POWER RQMT" |