Whether you are in need of military aviation parts, NSN components, or various forms of aerospace and defense parts, Aerospace Store is a single-sourcing solution with over 2 billion product listings readily available for purchase at any time with competitive pricing. You have reached the Request for Quote (RFQ) page for part number DB102202, a Dbp Microwave Inc component we feature that is listed with the NSN 5950012485938 and item name “Reactor Transformer.” For further identification, part number DB102202 was also specifically produced under CAGE Code 25656 and belongs to Federal Supply Class (FSC) 5950 Coils and Transformers. If you would like to receive specific options for procurement that have been tailored to your unique needs and restrictions alike, we ask that you please fill out and submit the form provided on this page with as much information as you can. Once our team has a chance to receive and review your offered details, a dedicated account manager will be in touch shortly after.
Note : We will not share your information to any third parties.
Items like part number DB102202 and others are all readily available with short lead times, and we boast rigorous quality-assurance practices to guarantee the caliber and reliability of every purchase made on our website. Beyond quality, we are fully committed to customer satisfaction, regularly exceeding industry expectations to ensure that we thoroughly and efficiently address every need. If you happen to be facing a time constraint that demands more specialized fulfillment solutions, please give us a call or email at any time to discuss the options we can provide. We are available around the clock and are always happy to assist, so do not hesitate to reach out for part number DB102202 and other various items of interest.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-248-5938 Item Description: Reactor Transformer | 5950 | 012485938 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | isc | rnvc | rncc | HCC | MSDS | SADC |
Db102202 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABHY | TURN QUANTITY | 1 4TH COMPONENT SINGLE PRIMARY" |
ABHY | TURN QUANTITY | 105 2ND COMPONENT SINGLE WINDING" |
ABHY | TURN QUANTITY | 12 3RD COMPONENT 3RD SECONDARY" |
ABHY | TURN QUANTITY | 25 3RD COMPONENT 4TH SECONDARY" |
ABHY | TURN QUANTITY | 32 3RD COMPONENT SINGLE PRIMARY" |
ABHY | TURN QUANTITY | 4 3RD COMPONENT 1ST SECONDARY" |
ABHY | TURN QUANTITY | 48 3RD COMPONENT 2ND SECONDARY" |
ABHY | TURN QUANTITY | 500 4TH COMPONENT SINGLE SECONDARY" |
ABHY | TURN QUANTITY | 7 1ST COMPONENT SINGLE WINDING" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.800 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ACYV | INDUCTANCE RATING | 10.00 MICROHENRIES NOMINAL 1ST COMPONENT SINGLE WINDING" |
ACYV | INDUCTANCE RATING | 90.00 MICROHENRIES MINIMUM 2ND COMPONENT SINGLE WINDING AND 3.10 MILLIHENRIES MAXIMUM 2ND COMPONENT SINGLE WINDING" |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL 2ND COMPONENT" |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL 3RD COMPONENT" |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL 4TH COMPONENT" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL 1ST COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE 3RD COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE 4TH COMPONENT" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO TERMINAL 3RD COMPONENT" |
ADAQ | BODY LENGTH | 3.300 INCHES MAXIMUM" |
ADAT | BODY WIDTH | 2.010 INCHES MAXIMUM" |
ADAU | BODY HEIGHT | 1.630 INCHES MAXIMUM" |
AGAV | END ITEM IDENTIFICATION | C5B ACFT; WSD: AIRCRAFT, GALAXY C-5" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP" |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE WINDING AND WINDING TURNS 1ST COMPONENT SINGLE WINDING" |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE WINDING AND WINDING TURNS 2ND COMPONENT SINGLE WINDING" |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 1ST SECONDARY AND WINDING TURNS 3RD COMPONENT 1ST SECONDARY" |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 2ND SECONDARY AND WINDING TURNS 3RD COMPONENT 2ND SECONDARY" |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 3RD SECONDARY AND WINDING TURNS 3RD COMPONENT 3RD SECONDARY" |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 4TH SECONDARY AND WINDING TURNS 3RD COMPONENT 4TH SECONDARY" |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT SINGLE PRIMARY AND WINDING TURNS 3RD COMPONENT SINGLE PRIMARY" |
BKPL | RATING METHOD | WINDING TURNS 4TH COMPONENT SINGLE PRIMARY" |
BKPL | RATING METHOD | WINDING TURNS 4TH COMPONENT SINGLE SECONDARY" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 3RD COMPONENT AND 6 SECONDARY 3RD COMPONENT" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 4TH COMPONENT AND 1 SECONDARY 4TH COMPONENT" |
CQPZ | WINDING CONDUCTOR SIZE | 0.00200 INCHES AMERICAN WIRE GAGE 1ST COMPONENT SINGLE WINDING" |
CQPZ | WINDING CONDUCTOR SIZE | 0.00500 INCHES AMERICAN WIRE GAGE 4TH COMPONENT SINGLE SECONDARY" |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 1ST SECONDARY" |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 2ND SECONDARY" |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 3RD SECONDARY" |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 4TH SECONDARY" |
CQPZ | WINDING CONDUCTOR SIZE | 0.02257 INCHES AMERICAN WIRE GAGE 2ND COMPONENT SINGLE WINDING" |
CQPZ | WINDING CONDUCTOR SIZE | 0.02535 INCHES AMERICAN WIRE GAGE 3RD COMPONENT SINGLE PRIMARY" |
CQPZ | WINDING CONDUCTOR SIZE | 0.02535 INCHES AMERICAN WIRE GAGE 4TH COMPONENT SINGLE PRIMARY" |
CRBZ | WINDING OPERATING CURRENT | 29.0 AMPERES DC MAXIMUM 2ND COMPONENT SINGLE WINDING" |
CRBZ | WINDING OPERATING CURRENT | 30.0 AMPERES DC NOMINAL 1ST COMPONENT SINGLE WINDING" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.046 3RD COMPONENT SINGLE PRIMARY" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.120 3RD COMPONENT 3RD SECONDARY" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.132 3RD COMPONENT 1ST SECONDARY" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.240 3RD COMPONENT 4TH SECONDARY" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.760 3RD COMPONENT 2ND SECONDARY" |
CRGS | DC RESISTANCE RATING IN OHMS | 14.000 4TH COMPONENT SINGLE SECONDARY" |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT" |
CWJS | WINDING OPERATING VOLTAGE | 0.10 AC VOLTS NOMINAL 1ST COMPONENT SINGLE WINDING" |
CWJS | WINDING OPERATING VOLTAGE | 15.60 AC VOLTS NOMINAL 3RD COMPONENT 4TH SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 2.00 AC VOLTS NOMINAL 2ND COMPONENT SINGLE WINDING" |
CWJS | WINDING OPERATING VOLTAGE | 2.50 AC VOLTS NOMINAL 3RD COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 20.00 AC VOLTS NOMINAL 3RD COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 30.00 AC VOLTS NOMINAL 3RD COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 7.48 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY" |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL" |
TTQY | TERMINAL TYPE AND QUANTITY | 28 TURRET" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABHY | TURN QUANTITY | 1 4TH COMPONENT SINGLE PRIMARY" |
ABHY | TURN QUANTITY | 105 2ND COMPONENT SINGLE WINDING" |
ABHY | TURN QUANTITY | 12 3RD COMPONENT 3RD SECONDARY" |
ABHY | TURN QUANTITY | 25 3RD COMPONENT 4TH SECONDARY" |
ABHY | TURN QUANTITY | 32 3RD COMPONENT SINGLE PRIMARY" |
ABHY | TURN QUANTITY | 4 3RD COMPONENT 1ST SECONDARY" |
ABHY | TURN QUANTITY | 48 3RD COMPONENT 2ND SECONDARY" |
ABHY | TURN QUANTITY | 500 4TH COMPONENT SINGLE SECONDARY" |
ABHY | TURN QUANTITY | 7 1ST COMPONENT SINGLE WINDING" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.800 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ACYV | INDUCTANCE RATING | 10.00 MICROHENRIES NOMINAL 1ST COMPONENT SINGLE WINDING" |
ACYV | INDUCTANCE RATING | 90.00 MICROHENRIES MINIMUM 2ND COMPONENT SINGLE WINDING AND 3.10 MILLIHENRIES MAXIMUM 2ND COMPONENT SINGLE WINDING" |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL 2ND COMPONENT" |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL 3RD COMPONENT" |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL 4TH COMPONENT" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL 1ST COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE 3RD COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE 4TH COMPONENT" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO TERMINAL 3RD COMPONENT" |
ADAQ | BODY LENGTH | 3.300 INCHES MAXIMUM" |
ADAT | BODY WIDTH | 2.010 INCHES MAXIMUM" |
ADAU | BODY HEIGHT | 1.630 INCHES MAXIMUM" |
AGAV | END ITEM IDENTIFICATION | C5B ACFT; WSD: AIRCRAFT, GALAXY C-5" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP" |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE WINDING AND WINDING TURNS 1ST COMPONENT SINGLE WINDING" |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE WINDING AND WINDING TURNS 2ND COMPONENT SINGLE WINDING" |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 1ST SECONDARY AND WINDING TURNS 3RD COMPONENT 1ST SECONDARY" |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 2ND SECONDARY AND WINDING TURNS 3RD COMPONENT 2ND SECONDARY" |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 3RD SECONDARY AND WINDING TURNS 3RD COMPONENT 3RD SECONDARY" |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 4TH SECONDARY AND WINDING TURNS 3RD COMPONENT 4TH SECONDARY" |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT SINGLE PRIMARY AND WINDING TURNS 3RD COMPONENT SINGLE PRIMARY" |
BKPL | RATING METHOD | WINDING TURNS 4TH COMPONENT SINGLE PRIMARY" |
BKPL | RATING METHOD | WINDING TURNS 4TH COMPONENT SINGLE SECONDARY" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 3RD COMPONENT AND 6 SECONDARY 3RD COMPONENT" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 4TH COMPONENT AND 1 SECONDARY 4TH COMPONENT" |
CQPZ | WINDING CONDUCTOR SIZE | 0.00200 INCHES AMERICAN WIRE GAGE 1ST COMPONENT SINGLE WINDING" |
CQPZ | WINDING CONDUCTOR SIZE | 0.00500 INCHES AMERICAN WIRE GAGE 4TH COMPONENT SINGLE SECONDARY" |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 1ST SECONDARY" |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 2ND SECONDARY" |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 3RD SECONDARY" |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 4TH SECONDARY" |
CQPZ | WINDING CONDUCTOR SIZE | 0.02257 INCHES AMERICAN WIRE GAGE 2ND COMPONENT SINGLE WINDING" |
CQPZ | WINDING CONDUCTOR SIZE | 0.02535 INCHES AMERICAN WIRE GAGE 3RD COMPONENT SINGLE PRIMARY" |
CQPZ | WINDING CONDUCTOR SIZE | 0.02535 INCHES AMERICAN WIRE GAGE 4TH COMPONENT SINGLE PRIMARY" |
CRBZ | WINDING OPERATING CURRENT | 29.0 AMPERES DC MAXIMUM 2ND COMPONENT SINGLE WINDING" |
CRBZ | WINDING OPERATING CURRENT | 30.0 AMPERES DC NOMINAL 1ST COMPONENT SINGLE WINDING" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.046 3RD COMPONENT SINGLE PRIMARY" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.120 3RD COMPONENT 3RD SECONDARY" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.132 3RD COMPONENT 1ST SECONDARY" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.240 3RD COMPONENT 4TH SECONDARY" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.760 3RD COMPONENT 2ND SECONDARY" |
CRGS | DC RESISTANCE RATING IN OHMS | 14.000 4TH COMPONENT SINGLE SECONDARY" |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT" |
CWJS | WINDING OPERATING VOLTAGE | 0.10 AC VOLTS NOMINAL 1ST COMPONENT SINGLE WINDING" |
CWJS | WINDING OPERATING VOLTAGE | 15.60 AC VOLTS NOMINAL 3RD COMPONENT 4TH SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 2.00 AC VOLTS NOMINAL 2ND COMPONENT SINGLE WINDING" |
CWJS | WINDING OPERATING VOLTAGE | 2.50 AC VOLTS NOMINAL 3RD COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 20.00 AC VOLTS NOMINAL 3RD COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 30.00 AC VOLTS NOMINAL 3RD COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 7.48 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY" |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL" |
TTQY | TERMINAL TYPE AND QUANTITY | 28 TURRET" |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote
|