Whether you are in need of military aviation parts, NSN components, or various forms of aerospace and defense parts, Aerospace Store is a single-sourcing solution with over 2 billion product listings readily available for purchase at any time with competitive pricing. You have reached the Request for Quote (RFQ) page for part number EC2020SFC, a Drs Power And Control Technologies component we feature that is listed with the NSN 5925009067811 and item name “Circuit Breaker.” For further identification, part number EC2020SFC was also specifically produced under CAGE Code 27192 and belongs to Federal Supply Class (FSC) 5925 Circuit Breakers. If you would like to receive specific options for procurement that have been tailored to your unique needs and restrictions alike, we ask that you please fill out and submit the form provided on this page with as much information as you can. Once our team has a chance to receive and review your offered details, a dedicated account manager will be in touch shortly after.
Note : We will not share your information to any third parties.
Items like part number EC2020SFC and others are all readily available with short lead times, and we boast rigorous quality-assurance practices to guarantee the caliber and reliability of every purchase made on our website. Beyond quality, we are fully committed to customer satisfaction, regularly exceeding industry expectations to ensure that we thoroughly and efficiently address every need. If you happen to be facing a time constraint that demands more specialized fulfillment solutions, please give us a call or email at any time to discuss the options we can provide. We are available around the clock and are always happy to assist, so do not hesitate to reach out for part number EC2020SFC and other various items of interest.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-906-7811 Item Description: Circuit Breaker | 5925 | 009067811 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | isc | rnvc | rncc | HCC | MSDS | SADC |
Ec2020sfc | 2 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE" |
ADAQ | BODY LENGTH | 2.987 INCHES MINIMUM AND 3.013 INCHES MAXIMUM" |
ADAT | BODY WIDTH | 1.464 INCHES MINIMUM AND 1.496 INCHES MAXIMUM" |
ADAU | BODY HEIGHT | 2.466 INCHES MINIMUM AND 2.594 INCHES MAXIMUM" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.552 INCHES MINIMUM AND 0.578 INCHES MAXIMUM" |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
AJEC | BOSS HEIGHT | 0.188 INCHES NOMINAL" |
AKPX | POLE QUANTITY | 2" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 10000.0 AC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 ALL LOCATIONS" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE" |
CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE" |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT" |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS" |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS" |
TEST | TEST DATA DOCUMENT | 81348-W-C-375 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING G" |
TTQY | TERMINAL TYPE AND QUANTITY | 4 CLIP" |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-W-C-375/6 GOVERNMENT SPECIFICATION" |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE" |
ADAQ | BODY LENGTH | 2.987 INCHES MINIMUM AND 3.013 INCHES MAXIMUM" |
ADAT | BODY WIDTH | 1.464 INCHES MINIMUM AND 1.496 INCHES MAXIMUM" |
ADAU | BODY HEIGHT | 2.466 INCHES MINIMUM AND 2.594 INCHES MAXIMUM" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.552 INCHES MINIMUM AND 0.578 INCHES MAXIMUM" |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
AJEC | BOSS HEIGHT | 0.188 INCHES NOMINAL" |
AKPX | POLE QUANTITY | 2" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 10000.0 AC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 ALL LOCATIONS" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE" |
CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE" |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT" |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS" |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS" |
TEST | TEST DATA DOCUMENT | 81348-W-C-375 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING G" |
TTQY | TERMINAL TYPE AND QUANTITY | 4 CLIP" |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-W-C-375/6 GOVERNMENT SPECIFICATION" |