Whether you are in need of military aviation parts, NSN components, or various forms of aerospace and defense parts, Aerospace Store is a single-sourcing solution with over 2 billion product listings readily available for purchase at any time with competitive pricing. You have reached the Request for Quote (RFQ) page for part number 2G4-5, a Ellis And Watts International Llc component we feature that is listed with the NSN 5925000096791 and item name “Circuit Breaker.” For further identification, part number 2G4-5 was also specifically produced under CAGE Code 98437 and belongs to Federal Supply Class (FSC) 5925 Circuit Breakers. If you would like to receive specific options for procurement that have been tailored to your unique needs and restrictions alike, we ask that you please fill out and submit the form provided on this page with as much information as you can. Once our team has a chance to receive and review your offered details, a dedicated account manager will be in touch shortly after.
Note : We will not share your information to any third parties.
Items like part number 2G4-5 and others are all readily available with short lead times, and we boast rigorous quality-assurance practices to guarantee the caliber and reliability of every purchase made on our website. Beyond quality, we are fully committed to customer satisfaction, regularly exceeding industry expectations to ensure that we thoroughly and efficiently address every need. If you happen to be facing a time constraint that demands more specialized fulfillment solutions, please give us a call or email at any time to discuss the options we can provide. We are available around the clock and are always happy to assist, so do not hesitate to reach out for part number 2G4-5 and other various items of interest.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-009-6791 Item Description: Circuit Breaker | 5925 | 000096791 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | isc | rnvc | rncc | HCC | MSDS | SADC |
2g4-5 | C | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE" |
ADAQ | BODY LENGTH | 2.530 INCHES NOMINAL" |
ADAT | BODY WIDTH | 2.280 INCHES NOMINAL" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.940 INCHES NOMINAL" |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL" |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.060 INCHES NOMINAL" |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW" |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL" |
AJEC | BOSS HEIGHT | 0.150 INCHES NOMINAL" |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.480 INCHES NOMINAL" |
AKPX | POLE QUANTITY | 3" |
APNQ | III ARC QUENCHING METHOD | MAGNETIC BLOWOUT" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE" |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
BBRJ | III SPECIAL HANDLING FEATURE | MAGNETIC" |
CMLP | THREAD QUANTITY PER INCH | 32" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES AC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC ALL LOCATIONS" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1500.0 AC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE" |
CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE" |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED" |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM" |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES" |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | EXTERNAL AT POLE ONE" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.500 MINIMUM AT 200 PCT ALL LOCATIONS AND 8.500 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT" |
CRTK | SWITCH TERMINAL TYPE | TURRET" |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 2.5 AC AND 1.0 DC" |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 50.0 DC" |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS" |
PKWT | UNPACKAGED UNIT WEIGHT | 14.000 OUNCES" |
THSD | THREAD SERIES DESIGNATOR | UNC" |
TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD" |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE" |
ADAQ | BODY LENGTH | 2.530 INCHES NOMINAL" |
ADAT | BODY WIDTH | 2.280 INCHES NOMINAL" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.940 INCHES NOMINAL" |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL" |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.060 INCHES NOMINAL" |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW" |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL" |
AJEC | BOSS HEIGHT | 0.150 INCHES NOMINAL" |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.480 INCHES NOMINAL" |
AKPX | POLE QUANTITY | 3" |
APNQ | III ARC QUENCHING METHOD | MAGNETIC BLOWOUT" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE" |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
BBRJ | III SPECIAL HANDLING FEATURE | MAGNETIC" |
CMLP | THREAD QUANTITY PER INCH | 32" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES AC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC ALL LOCATIONS" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1500.0 AC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE" |
CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE" |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED" |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM" |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES" |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | EXTERNAL AT POLE ONE" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.500 MINIMUM AT 200 PCT ALL LOCATIONS AND 8.500 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT" |
CRTK | SWITCH TERMINAL TYPE | TURRET" |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 2.5 AC AND 1.0 DC" |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 50.0 DC" |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS" |
PKWT | UNPACKAGED UNIT WEIGHT | 14.000 OUNCES" |
THSD | THREAD SERIES DESIGNATOR | UNC" |
TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD" |