Whether you are in need of military aviation parts, NSN components, or various forms of aerospace and defense parts, Aerospace Store is a single-sourcing solution with over 2 billion product listings readily available for purchase at any time with competitive pricing. You have reached the Request for Quote (RFQ) page for part number THK236T125, a General Electric Co Electric Cap component we feature that is listed with the NSN 5925009342792 and item name “Tripper Circuit Breaker.” For further identification, part number THK236T125 was also specifically produced under CAGE Code 60969 and belongs to Federal Supply Class (FSC) 5925 Circuit Breakers. If you would like to receive specific options for procurement that have been tailored to your unique needs and restrictions alike, we ask that you please fill out and submit the form provided on this page with as much information as you can. Once our team has a chance to receive and review your offered details, a dedicated account manager will be in touch shortly after.
Note : We will not share your information to any third parties.
Items like part number THK236T125 and others are all readily available with short lead times, and we boast rigorous quality-assurance practices to guarantee the caliber and reliability of every purchase made on our website. Beyond quality, we are fully committed to customer satisfaction, regularly exceeding industry expectations to ensure that we thoroughly and efficiently address every need. If you happen to be facing a time constraint that demands more specialized fulfillment solutions, please give us a call or email at any time to discuss the options we can provide. We are available around the clock and are always happy to assist, so do not hesitate to reach out for part number THK236T125 and other various items of interest.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-934-2792 Item Description: Tripper Circuit Breaker | 5925 | 009342792 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | isc | rnvc | rncc | HCC | MSDS | SADC |
Thk236t125 | 6 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE" |
ABHP | OVERALL LENGTH | 10.125 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 4.062 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 8.250 INCHES NOMINAL" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.312 INCHES NOMINAL" |
AKPX | III POLE QUANTITY | 3" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 125.0 AMPERES AC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600.0 AC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE" |
CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 100.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 275.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS MAXIMUM ALL LOCATIONS" |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS" |
PKWT | UNPACKAGED UNIT WEIGHT | 2.500 POUNDS" |
TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION" |
AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE" |
ABHP | OVERALL LENGTH | 10.125 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 4.062 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 8.250 INCHES NOMINAL" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.312 INCHES NOMINAL" |
AKPX | III POLE QUANTITY | 3" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 125.0 AMPERES AC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600.0 AC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE" |
CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 100.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 275.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS MAXIMUM ALL LOCATIONS" |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS" |
PKWT | UNPACKAGED UNIT WEIGHT | 2.500 POUNDS" |
TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION" |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote
|