Whether you are in need of military aviation parts, NSN components, or various forms of aerospace and defense parts, Aerospace Store is a single-sourcing solution with over 2 billion product listings readily available for purchase at any time with competitive pricing. You have reached the Request for Quote (RFQ) page for part number TQP230, a General Electric Co Outdoor Brea component we feature that is listed with the NSN 5925010042476 and item name “Circuit Breaker.” For further identification, part number TQP230 was also specifically produced under CAGE Code 03497 and belongs to Federal Supply Class (FSC) 5925 Circuit Breakers. If you would like to receive specific options for procurement that have been tailored to your unique needs and restrictions alike, we ask that you please fill out and submit the form provided on this page with as much information as you can. Once our team has a chance to receive and review your offered details, a dedicated account manager will be in touch shortly after.
Note : We will not share your information to any third parties.
Items like part number TQP230 and others are all readily available with short lead times, and we boast rigorous quality-assurance practices to guarantee the caliber and reliability of every purchase made on our website. Beyond quality, we are fully committed to customer satisfaction, regularly exceeding industry expectations to ensure that we thoroughly and efficiently address every need. If you happen to be facing a time constraint that demands more specialized fulfillment solutions, please give us a call or email at any time to discuss the options we can provide. We are available around the clock and are always happy to assist, so do not hesitate to reach out for part number TQP230 and other various items of interest.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-004-2476 Item Description: Circuit Breaker | 5925 | 010042476 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | isc | rnvc | rncc | HCC | MSDS | SADC |
Tqp230 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE" |
ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL" |
ADAT | BODY WIDTH | 1.478 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.312 INCHES NOMINAL" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.739 INCHES NOMINAL" |
AJEC | BOSS HEIGHT | 0.188 INCHES NOMINAL" |
AKPX | POLE QUANTITY | 2" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 TERMINAL" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES AC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE" |
CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE" |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 120.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS" |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS" |
TTQY | TERMINAL TYPE AND QUANTITY | 2 CLIP AND 2 COMPRESSION" |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE" |
ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL" |
ADAT | BODY WIDTH | 1.478 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.312 INCHES NOMINAL" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.739 INCHES NOMINAL" |
AJEC | BOSS HEIGHT | 0.188 INCHES NOMINAL" |
AKPX | POLE QUANTITY | 2" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 TERMINAL" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES AC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE" |
CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE" |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 120.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS" |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS" |
TTQY | TERMINAL TYPE AND QUANTITY | 2 CLIP AND 2 COMPRESSION" |