Whether you are in need of military aviation parts, NSN components, or various forms of aerospace and defense parts, Aerospace Store is a single-sourcing solution with over 2 billion product listings readily available for purchase at any time with competitive pricing. You have reached the Request for Quote (RFQ) page for part number PEI9999, a Precision Electronics Inc component we feature that is listed with the NSN 5950010730801 and item name “Transformer Power.” For further identification, part number PEI9999 was also specifically produced under CAGE Code 13483 and belongs to Federal Supply Class (FSC) 5950 Coils and Transformers. If you would like to receive specific options for procurement that have been tailored to your unique needs and restrictions alike, we ask that you please fill out and submit the form provided on this page with as much information as you can. Once our team has a chance to receive and review your offered details, a dedicated account manager will be in touch shortly after.
Note : We will not share your information to any third parties.
Items like part number PEI9999 and others are all readily available with short lead times, and we boast rigorous quality-assurance practices to guarantee the caliber and reliability of every purchase made on our website. Beyond quality, we are fully committed to customer satisfaction, regularly exceeding industry expectations to ensure that we thoroughly and efficiently address every need. If you happen to be facing a time constraint that demands more specialized fulfillment solutions, please give us a call or email at any time to discuss the options we can provide. We are available around the clock and are always happy to assist, so do not hesitate to reach out for part number PEI9999 and other various items of interest.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-073-0801 Item Description: Transformer Power | 5950 | 010730801 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | isc | rnvc | rncc | HCC | MSDS | SADC |
Pei9999 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.460 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.480 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.490 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABTB | MOUNTING HOLE DIAMETER | 0.180 INCHES MINIMUM SINGLE GROUP AND 0.240 INCHES MAXIMUM SINGLE GROUP" |
ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT" |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA AND DELTA-WYE" |
ADAQ | BODY LENGTH | 5.895 INCHES MAXIMUM" |
ADAT | BODY WIDTH | 4.600 INCHES MINIMUM AND 4.620 INCHES MAXIMUM" |
ADAU | BODY HEIGHT | 4.640 INCHES MAXIMUM" |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 14 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 2.2 AMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 8.7 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 8.7 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 14.60 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 25.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 32.60 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 32.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; FOURTEEN SECONDARY WINDINGS" |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TERMINAL BLOCK W/SCREWS" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.460 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.480 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.490 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABTB | MOUNTING HOLE DIAMETER | 0.180 INCHES MINIMUM SINGLE GROUP AND 0.240 INCHES MAXIMUM SINGLE GROUP" |
ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT" |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA AND DELTA-WYE" |
ADAQ | BODY LENGTH | 5.895 INCHES MAXIMUM" |
ADAT | BODY WIDTH | 4.600 INCHES MINIMUM AND 4.620 INCHES MAXIMUM" |
ADAU | BODY HEIGHT | 4.640 INCHES MAXIMUM" |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 14 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 2.2 AMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 8.7 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 8.7 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 14.60 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 25.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 32.60 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 32.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; FOURTEEN SECONDARY WINDINGS" |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TERMINAL BLOCK W/SCREWS" |