AS9120B, ISO 9001:2015, and FAA 0056B Accredited

Part 67821-41 071 with NSN 6130-01-480-4289 by Selex Elsag Ltd - Submit a Quote

Mfg Part Number: 67821-41 071

Item Name: Power Supply

Manufacturer: Selex Elsag Ltd

CAGE Code: U2248

Alternate P/N: 6782141071



FSG: 61 Electric Wire and Power and Distribution Equipment

Country: USA

NCB Code: 01

INC Code: 00740

Whether you are in need of military aviation parts, NSN components, or various forms of aerospace and defense parts, Aerospace Store is a single-sourcing solution with over 2 billion product listings readily available for purchase at any time with competitive pricing. You have reached the Request for Quote (RFQ) page for part number 67821-41 071, a Selex Elsag Ltd component we feature that is listed with the NSN 6130014804289 and item name “Power Supply.” For further identification, part number 67821-41 071 was also specifically produced under CAGE Code U2248 and belongs to Federal Supply Class (FSC) 6130 Converters Electrical Non Rotating. If you would like to receive specific options for procurement that have been tailored to your unique needs and restrictions alike, we ask that you please fill out and submit the form provided on this page with as much information as you can. Once our team has a chance to receive and review your offered details, a dedicated account manager will be in touch shortly after.

PRODUCT DETAILS “*” Required fields are compulsory

CONTACT INFORMATION

   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Note : We will not share your information to any third parties.

  • Upload RFQ SHEET
  • If you have more than one item, upload your spreadsheet here

Items like part number 67821-41 071 and others are all readily available with short lead times, and we boast rigorous quality-assurance practices to guarantee the caliber and reliability of every purchase made on our website. Beyond quality, we are fully committed to customer satisfaction, regularly exceeding industry expectations to ensure that we thoroughly and efficiently address every need. If you happen to be facing a time constraint that demands more specialized fulfillment solutions, please give us a call or email at any time to discuss the options we can provide. We are available around the clock and are always happy to assist, so do not hesitate to reach out for part number 67821-41 071 and other various items of interest.

NSN Information for Part Number 67821-41 071 with NSN 6130-01-480-4289, 6130014804289

NSNFSCNIINCLSHazmat DEMILCancelled NSN
6130-01-480-4289

Item Description:

POWER SUPPLY

6130014804289N
CIICHCCESD PMICCriticalityENAC
Part NumberiscrnvcrnccHCCMSDSSADC
67821-41/071525

Characteristics Data of NSN 6130-01-480-4289, 6130014804289

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH7.200 INCHES NOMINAL
ABKWOVERALL HEIGHT1.800 INCHES NOMINAL
ABMKOVERALL WIDTH4.200 INCHES NOMINAL
AKWCELECTRICAL POWER SOURCE RELATIONSHIPOPERATING
ANPMINPUT PHASESINGLE SINGLE OPERATING POWER RQMT
APNXINPUT VOLTAGE RATING94.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 264.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT
APPAOUTPUT VOLTAGE RATING-12.0 DC VOLTS NOMINAL 3RD POWER OUTPUT
APPAOUTPUT VOLTAGE RATING12.0 DC VOLTS NOMINAL 4TH POWER OUTPUT
APPAOUTPUT VOLTAGE RATING24.0 DC VOLTS NOMINAL 2ND POWER OUTPUT
APPAOUTPUT VOLTAGE RATING5.0 DC VOLTS NOMINAL 1ST POWER OUTPUT
APTQINPUT FREQUENCY RATING47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
BGQROUTPUT WATTAGE RATING80.0 WATTS MAXIMUM 1ST POWER OUTPUT
BGQROUTPUT WATTAGE RATING80.0 WATTS MAXIMUM 2ND POWER OUTPUT
BGQROUTPUT WATTAGE RATING80.0 WATTS MAXIMUM 3RD POWER OUTPUT
BGQROUTPUT WATTAGE RATING80.0 WATTS MAXIMUM 4TH POWER OUTPUT
CWGHOUTPUT CURRENT RATING1.0 DC AMPERES MINIMUM 1ST POWER OUTPUT
CWGHOUTPUT CURRENT RATING1.0 DC AMPERES MINIMUM 2ND POWER OUTPUT
CWGHOUTPUT CURRENT RATING1.0 DC AMPERES MINIMUM 3RD POWER OUTPUT
CWGHOUTPUT CURRENT RATING1.0 DC AMPERES MINIMUM 4TH POWER OUTPUT
CWHFOUTPUT CONNECTION QUANTITY1 1ST POWER OUTPUT
CWHFOUTPUT CONNECTION QUANTITY1 2ND POWER OUTPUT
CWHFOUTPUT CONNECTION QUANTITY1 3RD POWER OUTPUT
CWHFOUTPUT CONNECTION QUANTITY1 4TH POWER OUTPUT
CWHJOUTPUT CONNECTION TYPESCREW 1ST POWER OUTPUT
CWHJOUTPUT CONNECTION TYPESCREW 2ND POWER OUTPUT
CWHJOUTPUT CONNECTION TYPESCREW 3RD POWER OUTPUT
CWHJOUTPUT CONNECTION TYPESCREW 4TH POWER OUTPUT
CXCYPART NAME ASSIGNED BY CONTROLLING AGENCYMAP80 QUAD OUTPUT AC/DC POWER SUPPLY
FEATSPECIAL FEATURESDUAL MODE CONNECTORS PROVIDE TERMINAL BLOCK CONNECTIONS OR POPULAR SINGLE ROW MOLEX CONNECTOR MATING; COMES WITH OPTIONAL COVER
ABHPOVERALL LENGTH7.200 INCHES NOMINAL
ABKWOVERALL HEIGHT1.800 INCHES NOMINAL
ABMKOVERALL WIDTH4.200 INCHES NOMINAL
AKWCELECTRICAL POWER SOURCE RELATIONSHIPOPERATING
ANPMINPUT PHASESINGLE SINGLE OPERATING POWER RQMT
APNXINPUT VOLTAGE RATING94.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 264.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT
APPAOUTPUT VOLTAGE RATING-12.0 DC VOLTS NOMINAL 3RD POWER OUTPUT
APPAOUTPUT VOLTAGE RATING12.0 DC VOLTS NOMINAL 4TH POWER OUTPUT
APPAOUTPUT VOLTAGE RATING24.0 DC VOLTS NOMINAL 2ND POWER OUTPUT
APPAOUTPUT VOLTAGE RATING5.0 DC VOLTS NOMINAL 1ST POWER OUTPUT
APTQINPUT FREQUENCY RATING47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
BGQROUTPUT WATTAGE RATING80.0 WATTS MAXIMUM 1ST POWER OUTPUT
BGQROUTPUT WATTAGE RATING80.0 WATTS MAXIMUM 2ND POWER OUTPUT
BGQROUTPUT WATTAGE RATING80.0 WATTS MAXIMUM 3RD POWER OUTPUT
BGQROUTPUT WATTAGE RATING80.0 WATTS MAXIMUM 4TH POWER OUTPUT
CWGHOUTPUT CURRENT RATING1.0 DC AMPERES MINIMUM 1ST POWER OUTPUT
CWGHOUTPUT CURRENT RATING1.0 DC AMPERES MINIMUM 2ND POWER OUTPUT
CWGHOUTPUT CURRENT RATING1.0 DC AMPERES MINIMUM 3RD POWER OUTPUT
CWGHOUTPUT CURRENT RATING1.0 DC AMPERES MINIMUM 4TH POWER OUTPUT
CWHFOUTPUT CONNECTION QUANTITY1 1ST POWER OUTPUT
CWHFOUTPUT CONNECTION QUANTITY1 2ND POWER OUTPUT
CWHFOUTPUT CONNECTION QUANTITY1 3RD POWER OUTPUT
CWHFOUTPUT CONNECTION QUANTITY1 4TH POWER OUTPUT
CWHJOUTPUT CONNECTION TYPESCREW 1ST POWER OUTPUT
CWHJOUTPUT CONNECTION TYPESCREW 2ND POWER OUTPUT
CWHJOUTPUT CONNECTION TYPESCREW 3RD POWER OUTPUT
CWHJOUTPUT CONNECTION TYPESCREW 4TH POWER OUTPUT
CXCYPART NAME ASSIGNED BY CONTROLLING AGENCYMAP80 QUAD OUTPUT AC/DC POWER SUPPLY
FEATSPECIAL FEATURESDUAL MODE CONNECTORS PROVIDE TERMINAL BLOCK CONNECTIONS OR POPULAR SINGLE ROW MOLEX CONNECTOR MATING; COMES WITH OPTIONAL COVER

  Corresponding National Stock Number to 67821-41 071

Recently Viewed Parts
USA Flag

We are proud to supply every branch of the United States military


Why Choose Us?

Low Price Warrantied inventory at competitive prices
Find it fast Search the world's largest inventory of electronic components by manufacturer, category or part number
Get it fast All inventory ready to ship from our sellers
Quality guaranteed We sell only warrantied and traceable parts

Semiconductor's Certifications and Memberships

Thank You for Visiting.

We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

The only independent
distributor with a
NO CHINA SOURCING Pledge
  • All parts are stocked in the USA.
  • All parts are shipped from the USA.
  • All shipments must comply with U.S.A export laws.
  • No exceptions.
Fhf “We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.