Whether you are in need of military aviation parts, NSN components, or various forms of aerospace and defense parts, Aerospace Store is a single-sourcing solution with over 2 billion product listings readily available for purchase at any time with competitive pricing. You have reached the Request for Quote (RFQ) page for part number NL100WTR-2M-AAN-10, a Telemecanique Inc component we feature that is listed with the NSN 5930012765619 and item name “Switch Sensitive.” For further identification, part number NL100WTR-2M-AAN-10 was also specifically produced under CAGE Code 52090 and belongs to Federal Supply Class (FSC) 5930 Switches. If you would like to receive specific options for procurement that have been tailored to your unique needs and restrictions alike, we ask that you please fill out and submit the form provided on this page with as much information as you can. Once our team has a chance to receive and review your offered details, a dedicated account manager will be in touch shortly after.
Note : We will not share your information to any third parties.
Items like part number NL100WTR-2M-AAN-10 and others are all readily available with short lead times, and we boast rigorous quality-assurance practices to guarantee the caliber and reliability of every purchase made on our website. Beyond quality, we are fully committed to customer satisfaction, regularly exceeding industry expectations to ensure that we thoroughly and efficiently address every need. If you happen to be facing a time constraint that demands more specialized fulfillment solutions, please give us a call or email at any time to discuss the options we can provide. We are available around the clock and are always happy to assist, so do not hesitate to reach out for part number NL100WTR-2M-AAN-10 and other various items of interest.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-276-5619 Item Description: Switch Sensitive | 5930 | 012765619 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | isc | rnvc | rncc | HCC | MSDS | SADC |
Nl100wtr-2m-Aan-10 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | HOLE MOUNTED" |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND VIBRATION RESISTANT" |
ABMK | OVERALL WIDTH | 2.280 INCHES MINIMUM AND 2.340 INCHES MAXIMUM" |
ADTV | CASE MATERIAL | METAL" |
AFGK | ACTUATOR LENGTH | 1.470 INCHES MINIMUM AND 1.530 INCHES MAXIMUM" |
AFUQ | ACTUATOR STYLE | ROLLER ARM" |
AFUS | ACTUATOR HEIGHT | 0.513 INCHES NOMINAL" |
AFUV | ACTUATOR ROLLER DIAMETER | 0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM" |
AFUW | ACTUATOR ROLLER WIDTH | 0.220 INCHES MINIMUM AND 0.228 INCHES MAXIMUM" |
AFWC | HOUSING HEIGHT | 2.070 INCHES MINIMUM AND 2.130 INCHES MAXIMUM" |
AFWD | HOUSING LENGTH | 4.920 INCHES MINIMUM AND 4.980 INCHES MAXIMUM" |
AFWE | HOUSING WIDTH | 2.220 INCHES MINIMUM AND 2.280 INCHES MAXIMUM" |
AFWH | CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO LENGTH | 4.190 INCHES MINIMUM AND 4.250 INCHES MAXIMUM" |
AFWJ | CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO WIDTH | 1.780 INCHES MINIMUM AND 1.840 INCHES MAXIMUM" |
AFXE | MAXIMUM VOLTAGE RATING IN VOLTS | 600.0 AC AND 600.0 DC" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AXGY | MOUNTING METHOD | UNTHREADED HOLE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION 1ST SWITCH UNIT" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, ONE POSITION MOMENTARY 2ND SWITCH UNIT" |
CSJN | SWITCH ACTUATING FORCE | 11.0 OUNCES MINIMUM AND 12.0 OUNCES MAXIMUM" |
CXQQ | ACTUATOR MOVEMENT | 17.0 PRETRAVEL DEGREES NOMINAL AND 20.0 OVERTRAVEL DEGREES MINIMUM AND 35.0 OVERTRAVEL DEGREES MAXIMUM AND 11.0 DIFFERENTIAL DEGREES NOMINAL" |
CXQR | CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 400.000 MILLIAMPERES RESISTIVE DC AND 1.200 AMPERES RESISTIVE AC" |
TTQY | TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE" |
AAQL | BODY STYLE | HOLE MOUNTED" |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND VIBRATION RESISTANT" |
ABMK | OVERALL WIDTH | 2.280 INCHES MINIMUM AND 2.340 INCHES MAXIMUM" |
ADTV | CASE MATERIAL | METAL" |
AFGK | ACTUATOR LENGTH | 1.470 INCHES MINIMUM AND 1.530 INCHES MAXIMUM" |
AFUQ | ACTUATOR STYLE | ROLLER ARM" |
AFUS | ACTUATOR HEIGHT | 0.513 INCHES NOMINAL" |
AFUV | ACTUATOR ROLLER DIAMETER | 0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM" |
AFUW | ACTUATOR ROLLER WIDTH | 0.220 INCHES MINIMUM AND 0.228 INCHES MAXIMUM" |
AFWC | HOUSING HEIGHT | 2.070 INCHES MINIMUM AND 2.130 INCHES MAXIMUM" |
AFWD | HOUSING LENGTH | 4.920 INCHES MINIMUM AND 4.980 INCHES MAXIMUM" |
AFWE | HOUSING WIDTH | 2.220 INCHES MINIMUM AND 2.280 INCHES MAXIMUM" |
AFWH | CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO LENGTH | 4.190 INCHES MINIMUM AND 4.250 INCHES MAXIMUM" |
AFWJ | CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO WIDTH | 1.780 INCHES MINIMUM AND 1.840 INCHES MAXIMUM" |
AFXE | MAXIMUM VOLTAGE RATING IN VOLTS | 600.0 AC AND 600.0 DC" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AXGY | MOUNTING METHOD | UNTHREADED HOLE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION 1ST SWITCH UNIT" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, ONE POSITION MOMENTARY 2ND SWITCH UNIT" |
CSJN | SWITCH ACTUATING FORCE | 11.0 OUNCES MINIMUM AND 12.0 OUNCES MAXIMUM" |
CXQQ | ACTUATOR MOVEMENT | 17.0 PRETRAVEL DEGREES NOMINAL AND 20.0 OVERTRAVEL DEGREES MINIMUM AND 35.0 OVERTRAVEL DEGREES MAXIMUM AND 11.0 DIFFERENTIAL DEGREES NOMINAL" |
CXQR | CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 400.000 MILLIAMPERES RESISTIVE DC AND 1.200 AMPERES RESISTIVE AC" |
TTQY | TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE" |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote
|