Whether you are in need of military aviation parts, NSN components, or various forms of aerospace and defense parts, Aerospace Store is a single-sourcing solution with over 2 billion product listings readily available for purchase at any time with competitive pricing. You have reached the Request for Quote (RFQ) page for part number M554, a Way Wolff Associates Inc component we feature that is listed with the NSN 5930002598816 and item name “Switch Thermostatic.” For further identification, part number M554 was also specifically produced under CAGE Code 79230 and belongs to Federal Supply Class (FSC) 5930 Switches. If you would like to receive specific options for procurement that have been tailored to your unique needs and restrictions alike, we ask that you please fill out and submit the form provided on this page with as much information as you can. Once our team has a chance to receive and review your offered details, a dedicated account manager will be in touch shortly after.
Note : We will not share your information to any third parties.
Items like part number M554 and others are all readily available with short lead times, and we boast rigorous quality-assurance practices to guarantee the caliber and reliability of every purchase made on our website. Beyond quality, we are fully committed to customer satisfaction, regularly exceeding industry expectations to ensure that we thoroughly and efficiently address every need. If you happen to be facing a time constraint that demands more specialized fulfillment solutions, please give us a call or email at any time to discuss the options we can provide. We are available around the clock and are always happy to assist, so do not hesitate to reach out for part number M554 and other various items of interest.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-259-8816 Item Description: Switch Thermostatic | 5930 | 002598816 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | isc | rnvc | rncc | HCC | MSDS | SADC |
M554 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AASA | THREAD LENGTH | 1.812 INCHES NOMINAL SINGLE THREADED BUSHING" |
ABHP | III OVERALL LENGTH | 5.375 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 1.812 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.312 INCHES NOMINAL" |
AEVT | CAPILLARY TUBE LENGTH | 2.750 INCHES NOMINAL" |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE" |
AWTN | OPERATING TEMP RATING | 50.0 DEG FAHRENHEIT MINIMUM AND 240.0 DEG FAHRENHEIT MAXIMUM" |
AXGY | MOUNTING METHOD | THREADED BUSHING" |
CMLP | THREAD QUANTITY PER INCH | 14 SINGLE THREADED BUSHING" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQJX | NOMINAL THREAD SIZE | 0.750 INCHES SINGLE THREADED BUSHING" |
CSCF | TERMINAL TYPE | TAB W/SCREW" |
CTHF | CONTACT LOAD CURRENT RATING | 1.2 AMPERES RESISTIVE LOAD FOURTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.4 AMPERES RESISTIVE LOAD THIRD VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 3.7 AMPERES RESISTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 7.4 AMPERES RESISTIVE LOAD FIRST VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE" |
CTYM | CONTACT ADJUSTMENT RANGE | +100.00/+240.00 ACTUATION POINT DEGREES FAHRENHEIT" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL THIRD VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL FOURTH VOLTAGE" |
FEAT | SPECIAL FEATURES | COILED CAPILLARY TEMP SENSING ELEMENT IS IMMERSED DIRECTLY INTO WATER" |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID" |
THSD | THREAD SERIES DESIGNATOR | UNS SINGLE THREADED BUSHING" |
AASA | THREAD LENGTH | 1.812 INCHES NOMINAL SINGLE THREADED BUSHING" |
ABHP | III OVERALL LENGTH | 5.375 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 1.812 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.312 INCHES NOMINAL" |
AEVT | CAPILLARY TUBE LENGTH | 2.750 INCHES NOMINAL" |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE" |
AWTN | OPERATING TEMP RATING | 50.0 DEG FAHRENHEIT MINIMUM AND 240.0 DEG FAHRENHEIT MAXIMUM" |
AXGY | MOUNTING METHOD | THREADED BUSHING" |
CMLP | THREAD QUANTITY PER INCH | 14 SINGLE THREADED BUSHING" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQJX | NOMINAL THREAD SIZE | 0.750 INCHES SINGLE THREADED BUSHING" |
CSCF | TERMINAL TYPE | TAB W/SCREW" |
CTHF | CONTACT LOAD CURRENT RATING | 1.2 AMPERES RESISTIVE LOAD FOURTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.4 AMPERES RESISTIVE LOAD THIRD VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 3.7 AMPERES RESISTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 7.4 AMPERES RESISTIVE LOAD FIRST VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE" |
CTYM | CONTACT ADJUSTMENT RANGE | +100.00/+240.00 ACTUATION POINT DEGREES FAHRENHEIT" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL THIRD VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL FOURTH VOLTAGE" |
FEAT | SPECIAL FEATURES | COILED CAPILLARY TEMP SENSING ELEMENT IS IMMERSED DIRECTLY INTO WATER" |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID" |
THSD | THREAD SERIES DESIGNATOR | UNS SINGLE THREADED BUSHING" |